Ul 1598 luminaires pdf

All of dialights long life led luminaires are designed to meet the most demanding specification criteria while offering maximum energy savings, reduced maintenance costs, and a superior quality of light. Ul llc is a global safety certification company headquartered in northbrook, illinois. Fluorescent luminaire ul 1598 revisions ge lighting. Ul 1598 luminaires ul 8750 led equipment for use in lighting ul 48 electric signs ul 153 portable luminaires ul 234 lowvoltage lighting fixtures for use in rvs ul 676 underwater lighting fixtures ul 924 emergency lighting and power equipment. The difference between dry, wet, and damp locations. The rigalite led luminaires are the perfect combination of.

Established in 1894 as the underwriters electrical bureau a bureau of the national board of fire underwriters, it was known throughout the 20th century as underwriters laboratories and participated in the safety analysis of many of that centurys new technologies. Ul led safety standards the ul mark means that when a product left its manufacturing location, or modified per ul approved instructions, it complieds with requirements in the applicable ul standard 8750 light emitting diode led equipment for use in lighting products 1598 luminaires trinational standard. However, there are national and local requirements for interior luminaires to be wet location listed in areas such as bathrooms and above showers. This zone is all encompassing and includes the space directly over the tub or shower stall. Individual component listings in ulmaintained directories also referred to as yellow cards provide. The release of this document also saw the harmonization of ul and csa standard requirements with. Revision of bonding circuit impedance test to revert back to the previous ul 1570 series standards 2. Find the most uptodate version of ul 1598 at engineering360. Hookm353 ul1598a ul1598 occupancy sensor loopm353 tunnel sensor pph480u text. Recommendations for testing and evaluating luminaires used in. Since 1938, we have been at the forefront of lighting technology, providing industry. Standard for supplemental requirements for luminaires.

Meets the requirements of the 2017 national electrical code. Product catalogproduct catalog volume xviii, issue. Ul certification customers have free access to ul standards, not including ul iec based. If a luminaire is modified using offtheshelf parts instead of a ul certified retrofit kit. Ul certified retrofit kits include parts and instructions that have been verified to confirm that the modified luminaire would comply with the ul standard for luminaires ul 1598 when installed according to the instructions. Ul 1598 complete document 3rd edition, january 11, 10. Three 12 threaded conduit entry points allow for thrubranch wiring. Recessed housings for nonfirerated installations active, most current details.

Dmf lighting offers a number of luminaires, such as the drdhdrd2mdrd2t, that are ul 1598 standard for safety luminaires tested and marked suitable for wet location. Ul1598 rated led highlow bay flood light luminaire introduction this high bay low bay flood light is designed for illumination of industrial location and uses the latest in solid state lighting technology for long life, low maintenance, and high efficiency. Pgim28, based on the type of label product and the enduse application see table 1 for additional details on each category. Ul is a global independent safety science company offering expertise across three strategic businesses. Ul requirements and standards when investigating lighting products utilizing led circuitry, they are first evaluated using the appropriate ul standard for safety for the end product, such as the ul 1598 standard for safety for luminaires, or the ul 48 standard for safety for electric signs. Fluorescent luminaire ul 1598 revisions new compliance standard september 2010 ul 1598 for fluorescent luminaires what ballasts and fixtures are affected. Underwriters laboratories ul add to alert pdf add to alert. Ul 1598 ul standard for safety luminaires engineering360.

The latest edition of ansiul 1598 the 4th edition was issued in september 2018. Our breadth, established objectivity and proven history mean we are a symbol of trust, enabling us to help provide peace of mind to all. National electrical code nec, ansinfpa 70, and with the mexican national electrical code, nom001sede. In particular, ssl luminaires submitted for energy star qualification must be tested and certified to ansiul 159804 or ansiul 15305 standards. Optical assemblies include impact resistant borosilicate refractive glass. A location not normally subject to dampness, but may include a location subject to temporary dampness, as in the case of a. Ul 1598 amendment only revision pages, october 17, 12. Ul 1598 listed luminaires and thus they will serve both on normal power and as emergency luminaires during a power outage. This standard applies to luminaires for use in nonhazardous locations and that are intended for installation on branch circuits of 600 v nominal or less between conductors in accordance with the canadian electrical code, part i cec, csa c22.

Installation clearance requirements for recessed luminaries. Dmf lighting offers a number of luminaires, such as the drdhdrd2mdrd2t, that are ul 1598 standard for safety luminaires tested. Operate the luminaire in the appropriate ul 1598 apparatus for. Ansiul 15982008 gost pdf,bs pdf,ansi pdf,api pdf,asme. Ansiul 1598 is a national safety standard for lightingluminaires for use within north america. Update on lighting standards that impact led and nonled. Reference publications ansiul 2108 low voltage lighting systems, 1st edition ansiul 1598 luminaires, 2nd edition 3 power units. Ul certification customers have free access to ul standards, not including ul iec based standards. Ansiul 15982004 standard for safety for luminaires,ics. Durable, diecast aluminum housing with 4 12 nps side conduit entries.

Osha has approved a number of organizations as nationally recognized testing laboratories nrtls, and can. Available in cool 5000k or neutral 4000k led color temperatures cct. In december 2000, the first edition of ul 1598 was issued which combined ul 1570, ul 1571, and ul 1572 into one standard. F2 labs can evaluate and test your product, help you through the ul certification process and enable you to certify your product to the ul requirements through a nationally. Documents sold on the ansi standards store are in electronic adobe acrobat pdf format, however some iso and iec standards are available from amazon in hard copy format. Standard ul 1598 contains the product construction and performance requirements for recessed luminaires. Ul 1598 2008sep17 ul standard for safety lumnaresthrd edton reprnt wth revsons through and ncludng october 17 2012. Certificate of compliance certificate number 20161010e485996 report reference e48599620160927 issue date 2016october10 bruce mahrenholz, director north american certification program ul llc any information and documentation involving ul mark services are provided on behalf of ul llc ul or any authorized licensee of ul. What you should know about ul certified retrofit kits. However, the wiring of the normal and emergency power circuits cannot be intermixed in the luminaires that are not part of the emergency lighting circuit. Industry standard illumination solutions and warranty epcos led luminaires are etl listed and meet ul 1598 standards. View abstract product details document history ul 1598 complete document 3rd edition, october 17, 12. We also offer two different types of subscriptions. Energy star manufacturers guide for qualifying ssl luminaires sept.

Cest to learn more about the safety standard for horticultural luminaires, ul 8800, and the ul s 8000, the horticultural lighting performance specification. Ul 1598 crd ul standard for safety luminaires section paragraph reference. Luminaires trinational standard with ul 1598 and nmxj3071ance preface this is the harmonized ance, csa group, and ul standard for luminaires. National electrical code nec, ansinfpa 70, and with the mexican national. Ip, nema and ul rating codes anaheim automation, inc. For example, there was ul 1570 for fluorescent luminaires, ul 1571 for incandescent luminaires, and ul 1572 for hid luminaires. Ul 1598 wet location listed and ip66 ingress protection rated. Product catalogproduct catalog volume xviii, issue 1volume. Ul certifies marking and labeling systems under five different categories, pgdq28, pgji28, pggu28, pgis2 and. Pdf acrobat reader or word version doc document file size.

Department of energy energy star manufacturers guide. Attach temperature sensors to the lamp and the ballast or driver, if needed at the manufacturerspecified locations. Optical highly reflective anodized aluminum reflectors provide high efficiency illumination. Summary of substantive changes, ul 1598 page 1 summary of substantive changes between the 3rd edition, dated september 17, 2008, including updates through october 17, 2012, and the 4th edition, dated august 28, 2018 of ul 1598 luminaires. Damage to lighting fixture sockets from an electric arc can have serious consequences. It is the third edition of nmxj3071ance, the fourth edition of csa c22.

993 1383 1530 134 745 882 1531 531 817 507 353 517 1506 941 683 433 1343 1541 714 911 888 617 1306 2 1200 1582 1056 201 1595 755 393 187 1240 234 1294 172 946 1588 1030 896 1280 1109 1224 40 1136 1072